Floormap3di-r Mfl Tank Inspection Work -

This is the killer feature. Unlike traditional MFL where you scan first and analyze later, the 3Di-R builds a live top-down and cross-sectional view. You can see a suspected pit’s shape and depth while the robot is still over it. This has cut our re-scan rate by 70%.

The system delivers distinct data density and positioning tracking metrics over standard manual "stop-on-defect" alternative equipment. Specification 256 Hall Effect sensors across 64 acquisition channels Scanning Resolution 4.6 mm × 2.0 mm physical scan grid Maximum Scan Width 300 mm (12 inches) Scanning Speed Variable electric propulsion up to 1.0 m/s (3.3 ft/s) Plate Thickness Range 5.0 mm to 16.0 mm (3/16 to 5/8 inches) Max Non-Magnetic Coating Thickness Up to 6.0 mm (1/4 inch) Positional Accuracy floormap3di-r mfl tank inspection

Combines Magnetic Flux Leakage (MFL) for detecting volumetric material loss with Surface Topology Air-gap Reluctance Sensors (STARS) to distinguish between top-side and bottom-side corrosion. This is the killer feature

Yes, for our fleet size. But I’d also hire a dedicated data analyst—this tool’s output is too rich for a busy field technician to interpret alone on a laptop. This has cut our re-scan rate by 70%

In continuous use, the Rover-R gets about 4 hours. A full tank floor often takes 6-8 hours of scan time. You will need a second hot-swappable battery or a very long extension cord for the tether.